PP-384-S Series Personal Pipettor™

The PP-384-S series offers 384 channel high performance pipetting that is ideal for low volume multichannel microplate pipetting and for serial dilution applications. The microprocessor-controlled pipetting mechanism provides accurate and precise pipetting of microliter volumes of samples into 96, 384 or 1536-well microplates. The high-speed pipetting system provides short processing times by delivering liquids through up to 384 channels simultaneously with precise volume control.

PP-384-S

The Personal Pipettor (PP) is a popular series of affordable liquid handling systems with the versatility and reliability required for today’s demanding laboratory environment. The PP series offers the majority of automated features that many laboratories need at a reasonable price, making it possible for each technician to truly have their own “personal” pipettor.

The PP-384-S series use Apricot Designs’ unique head design which employs high-precision manufacturing to produce reasonably-priced heads that are independent of the pipetting mechanism. The operator can load and unload pipetting heads in a manner of seconds, allowing simple and easy set-up for the task at hand. The PP-384-S can be manually indexed if necessary for accessing 384-well plates with a 96-channel head or for serial dilutions.

Features

  • Flexible design for liquid transfers and pipetting operations for 96, 384 and 1536-well microplates and
    can also be used for serial dilutions by row or column.
  • Uses the unique all-electric easy-change head system from Apricot Designs, allowing the user to build a diverse head library with a reasonable investment. The heads are interchangeable with other Apricot pipettors.
  • Economical and simple 1-position deck provides low capital investment and smallest footprint.
  • Easily controlled through simple front-panel buttons; requires minimal operator training and no external computer is required.
  • Small footprint conserves bench space and fits easily into suitably-sized hoods.

Options

  • Fixed tip heads with 8, 12, 16, 24, 96 and 384 channels.
  • Disposable tip heads with 8, 12, 16, 24, 96 or 384 channels for Apricot ESP tips, Apricot 550 tips, or Biomek® FX tips.
  • Tip washing system with recirculating pump.
  • Optional manual indexer for 384 microplates (with 96-channel head) or serial dilutions.

Applications

  • Plate replication
  • Plate reformatting
  • Reagent addition
  • Compound addition
  • Serial dilution (by row or column)

Specifications

  • Dispensing Precision

<2% CV at 1 ul (96) <2.8% CV at 1 ul (384) <2% CV at 5ul

  • Dispensing Accuracy

+/- 1% at 1 ul (96) +/- 1.25% at 1 ul (384)

  • Resolution

0.1 ul 384/96 offset)

  • Pipette Volume

0.5 - 125 ul (384)

  • Dimensions

11”W x 12”D x 18.5”H 280W x 305D x 457H mm

  • Weight

Approx. 41 lbs (18.7 kg)

  • Power

100 to 240 VAC, 50/60 HZ

  • Operating Temperature

50 - 100 ºF

  • Warranty

12-month extensive manufacturer warranty

Extended 12-month warranty and Annual Service plan are also available. Contact factory or authorized dealers for detail

Accessories

Fixed Tip Heads. All fixed tip heads feature stainless steel tips with PTFE coating on inside and outside and have an internal diameter of 0.032 inch. Custom heads for unique or new applications are also available.

Part Number

Picture (click to enlarge) Number of channels Maximum volume per tip (ul) Plate compatibility Serial Dilution
125-A-01-023
(Requires Wash Manifold 125-A-09-384)
pipettor head
384
125
384, 1536*
None
125-A-02-023-25U
(Requires Wash Manifold 125-A-09-384)
pipettor head
384
25
384, 1536*
None
125-A-01-023-SC-S
(Requires Wash Manifold 125-A-09-384-SC)
pipettor head
16
125
384, 1536*
Columns only
125-A-01-023-SR
(Requires Wash Manifold 125-A-09-384-SR)
pipettor head
24
125
384, 1536*
Rows only
125-A-03-023
(Requires Wash Manifold 125-A-09-096)
pipettor head
96 (offset)
125
96,384*
None
125-A-04-023-25U
(Requires Wash Manifold 125-A-09-096)
pipettor head
96 (offset)
25
96,384*
None
125-A-03-023-SC-S
(Requires Wash Manifold 125-A-09-096-SC)
pipettor head
8 (offset)
125
96,384*
Columns only
125-A-03-023-SR
(Requires Wash Manifold 125-A-09-096-SR)
pipettor head
12 (offset)
125
96,384*
Rows only

* The PP-384-S can be manually indexed as to position the tips for these plates.

Disposable Tip Heads. Custom heads for unique or new applications are also available.

Part Number

Picture (click to enlarge)

Compatible Tips

Number of channels Maximum volume per tip (ul) Plate compatibility Serial Dilution
384-A-01-EZL
(EZ-LOAD)

pipettor head
Apricot ESP
384
125
384, 1536*
Rows or Columns **
384-A-01-EZL-096
(EZ-LOAD)
pipettor head
Apricot ESP
96 (offset)
125
384, 1536*
Rows or Columns ***
TPS384-A-01-ESP
(Requires 125-A-11 Tip Loader / Ejector)
pipettor head
Apricot ESP
384
125
384, 1536*
None
TPS384-A-01-096ESP
(Requires 125-A-11 Tip Loader / Ejector
pipettor head
Apricot ESP
96 (offset)
125
96, 384*
None
384-A-01-ESP-SC-M pipettor head
Apricot ESP
16
125
384
Columns
384-A-01-ESP-SR
pipettor head
Apricot ESP
24
125
384
Rows
384-A-01-ESP-096-SC-M
pipettor head
Apricot ESP
8
125
384
Columns
384-A-01-ESP-096-SR
pipettor head
Apricot ESP
12
125
384
Rows
125-A-05-55N
(Requires Tip Loader / Ejector 550-A-45N, Tip Holder 550-A-04-46N and Lube Box 550-A-08
pipettor head
Apricot 550
NOTE Max volume will the 125 ul per tip
96 (offset)
125
96, 384*
Rows or Columns ****
125-A-06-20N
(Requires Tip Loader / Ejector 550-A-45N and Tip Holder 550-A-04-20N)
pipettor head
Biomek 25, 50 & 250 ul
96 (offset)
125
96, 384*
Rows or Columns ****

* The PP-384-S can be manually indexed as to position the tips for these plates.
** Use Insert 384-A-01-EZL-SC for column serial dilution or Insert 384-A-01-EZL-SR for row serial dilution.
*** Use Insert 384-A-01-096-ESP-SC for column serial dilution or Insert 384-A-01-096-ESP-SR for row serial dilution.
**** The operator can manually load one row or one column of tips for serial dilution operations.

Accessories.

Part Number

Picture (click to enlarge) Description Compatible head
125-A-09-384
Wash Manifold
wash manifold
Wash manifold fits over top of 384 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023, 125-A-02-023-25U, 125-A-05-55-41F
125-A-09-384-SC
Wash Manifold
wash manifold
Wash manifold fits over top of 16 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023-SC-M
125-A-09-384-SR
Wash Manifold
wash manifold
Wash manifold fits over top of 24 channel fixed tip head. The head is washed by connecting to a faucet.
125-A-01-023-SR
125-A-09-096
Wash Manifold
wash manifold
Wash manifold fits over top of 96 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023, 125-A-04-023-25U
125-A-09-096-SC
Wash Manifold
wash manifold
Wash manifold fits over top of 8 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023-SC-M
125-A-09-096-SR
Wash Manifold
wash manifold
Wash manifold fits over top of 12 channel fixed tip head. The head is washed by connecting to a faucet. 125-A-03-023-SR
125-A-11
Tip Loader/Ejector
tip loader
Tool for manually loading loading and ejecting tips.
TPS384-A-01-ESP, TPS384-A-01-096ESP

550-A-45N
Tip Loader/Ejector
tip loader
Tool for manually loading loading and ejecting tips. 125-A-05-55-41DN, 125-A-05-55N, 125-A-06-20N
550-A-04-46N
Tip Supporting Holder
tip holder
Supports rack of Apricot 550 tips for the 550-A-45N Tip Loader/Ejector.
125-A-05-55-41DN, 125-A-05-55N
550-A-04-20N
Tip Box Spacer
tip holder
Supports Biomek tip rack for the 550-A-45N Tip Loader/Ejector.
125-A-06-20N
550-A-08
Lube Box
lube box
Pipetting head lubrication box for reliable seal of mandrel o-rings.
125-A-05-55-41DN
384-A-11
Tip Washing System
wash system
Tip washing system controlled by pipettor software interface.
All
550-A-16
Cooling Plate, horizontal ports
cooling plate
Installed on the deck; Requires recirculating bath.
All
550-A-16P
Cooling Plate, perpendicular ports
cooling plate
Installed on the deck; Requires recirculating bath.
All
125-0-MI
Manual XY Indexer
indexer
For 96/384 well plates and serial dilutions.
All